Lenze EDB9300UES User Manual

Page 46

Advertising
background image

Technical Data

BA8230

41

Outputs (encoder interface)

1 output for encoder track signals for further processing

Configuration:

2 differential outputs, separate potential
(+5 V isolated) for 2 incremental encoders
tracks offset through 90°
1 differential output, separate potential
(+5 V isolated) for the zero pulse track

Voltage level:

DC +5 V (15 V and 24 V in preparation)

Load rating per track:

20 mA

Incremental encoder supply

Configuration:

Switch controller output / internal

Voltage level:

5 V / 15 V / 24 V adjustable

Rating:

350 mA

The supply for the incremental encoder can be switched to “external” using hook
switches S50A and S50B. The incremental encoder is then fed from an external
voltage source through the “External voltage source” input.
Switch position 1 = “internal”, 2 = “external”.
The “external voltage source” may be max. DC +24 V.

Unit software required

From 8230 frequency inverter

Unit software SW V2.0




Note:

The procedure for connecting option boards through adapter cables must be followed
accurately. If several option boards are used, the following procedures must be
observed:

The encoder interface must always be connected directly at the control board,
using the shortest possible cable.


Show/Hide Bookmarks

Advertising