4.4.8 Diagnosis

Error: First value

This parameter outputs the actual error which resulted in a 8230 frequency inverter
error shut-down (the first error). This error is also written into the error log with the
time details. The entry in the parameter “Error: First value” is deleted by the control
command “Acknowledge”.

Output event no.:

This parameter outputs the contents of one of the 32 items in the event log as a
message. It is therefore possible to read out the logged events through the control
unit.
The number entered (1 ... 32) corresponds to the relevant position in the event log
whereby event no. 32 is the oldest entry and no. 1 is the most recent.
When the number is input, the corresponding event is transferred from the event log
to the 8230 frequency inverter BDE control unit display with the timing details.

Output error no.:

This parameter outputs the contents of one of the 32 positions in the error log as a
message. It is therefore possible to read out logged messages via the control unit.
The number entered (1 ... 32) corresponds to the relevant position in the error log,
whereby error no. 32 is the oldest entry and no. 1 is the most recent.
When the number is input, the appropriate error is transferred from the error log to the
8230 frequency inverter BDE control unit display with the timing details.

4.4.9 Password

The “Access” menu controls authority to access the user interface. Three levels of
protection are available to the operator:

Level 0

- Always visible

Level 1

- Protected

Level 2

- Hidden

Level 0 is active as standard.

Levels 1 and 2 are accessed by entering the appropriate password (the password for
level 1 or the password for level 2). The active level determines the range of
parameters displayed and accessible. You can switch back to level “0” by entering “0”
for the parameter “Protection level”.

Protection level

Parameters for displaying and switching the active protection level.

Level 0
Level 0 is active without a password.

Additional parameters:

- Standard parameters.