Technical Data

10

BA8230

2.3 System data

Mains supply voltage

3AC 400 ... 460 V; +10/-15 % ... 480 V; +6/-15 %

Mains frequency

50 ... 60 Hz ±5 %

Power factor
- Mains base frequency

cos

ϕ

1

> 0.97

- Total at rated current

depending on mains
impedance

λ

N

» 0.88 ind - 0.93 ind

Output voltage

3AC 0 ... U

mains

Approvals

prEN50178:1994/VDE0160
CE mark according to low voltage directive

Efficiency
at rated power

0.97

Overload factor

1.2 for max. 60 s at rated current 1.2
1.5 for max. 60 s at rated current 1.5
cycle time

10 min

Min. operating frequency

With encoder

0 Hz

Without encoder

motor:

1 Hz

regenerative:

2.5 Hz

Max. operating frequency

300 Hz

Speed adjustment range

for speed control
without encoder

with encoder

1:50

1)

>1:1000

1)

The adjustment range is 1:20 in regenerative
operation using the control structure “Speed
control without encoder”

Speed accuracy

for speed control
without encoder

with encoder
with digital demand preset

0.5 %

0.05 %

Torque rise times

For speed control
with or without encoder
2 ... 8 ms

Frequency resolution

10 mHz standard

adjustable with parameter f

100

Frequency stability for
frequency control

<0.01 % standard
<0.001 % option, on application