Parameter setting – Lenze EDB9300UES User Manual

Page 151

Advertising
background image

Commissioning Report

146

BA8230

Parameter setting

Object-Nr.

Parameter

Default setting

Unit

Value

04=ANALOG I/O’s

3240

Main demand. 27/28

0...10V/0...20mA

................

3210

Max. main demand

100.00

%

................

3211

Min. main demand

0.00

%

................

3216

Zero range main

1)

0.5

%

................

3241

Add.demand 29/30

0...10V/0...20mA

................

3218

Max. add demand

100.00

%

................

3219

Min. add demand

0.00

%

................

321A

Zero range add. d.

1)

0.5

%

................

310E

Main + add demand

No

................

310A

4-20mA monitor

Trip

................

3F00

A-output 1:33

Output frequency

................

3F01

A-output 2:35

Motor current

................

3F30

Skaling A-output 1

100.00

%

................

3F31

Skaling A-output 2

100.00

%

................

05=DIGITAL I/O’s

3250

D-input 1:14

Motpot up

................

3251

D-input 2:15

Motpot down

................

3252

D-input 3:16

Jogging

................

3F05

D-Ausgang1 23/24

Speed = ref

................

310D

Invert:23/24

No

................

3223

Band speed = ref.

24.90

1/min

................

3222

Band speed = zero

2.93

1/min

................

3221

Reference speed

750.05

1/min

................

3224

Ref. Load current

100.00

%

................

06=RATINGS

2211

Inverter-Type

................

2222

Inverter currents

3)

Unit type dependent, not adjustable

2212

Mains voltage

400

V

................

2214

Type of load

squared torque

................

2215

Break type

-

3)

................

2281

Nom.motor power

-

4)

kW

................

2284

Nom.motor voltage

380

4)

V

................

2288

Nom.motor speed

1460

4)

1/min

................

2287

Nom.motor frequ.

50

4)

Hz

................

2289

Star Delta

Stern

4)

................

2283

Nom.motor current

-

4)

A

................

2285

cos phi

0.85

4)

................

22C7

Motortype

3)

-

3)

................

2286

Stall/Nom. torque

3.0

4)

................

2294

R-stator + R-cable

1)

0.1924

4)

Ohm

................

1)

Protection Level 1

3)

Unit type dependent

4)

Motor type dependent

Code:

Date

Comm. No.

Contac.

FB No.:

Commissioning report

8230 frequency inverter

Drive data

Check.

Serial.No.:

Sheet 6

Show/Hide Bookmarks

Advertising