Operation and Software

120

BA8230

Select fixed speed 1

Select fixed speed 2

Activated fixed speed

0

0

"Fixed speed 1"

1

0

"Fixed speed 2"

0

1

"Fixed speed 3"

1

1

"Fixed speed 4"

"Fixed speed 1" to "Fixed speed 4" are specified in 02 = APPLICATION
PARAMETERS.

IMPORTANT!

If the function of the D-Input terminal :15 is not set to "Select fixed speed 2", the
selection matrix for Select fixed speed 2 is 0.

The active fixed speeds are only effective if the parameter for MANUAL demand or
AUTO demand in Menu 03 Configuration is set to fixed speed.

D-Input 3 terminal 16

This parameter determines the function of the digital control input at terminal :16. The
function is active at logic “High”.

Select list:

- Jogging
- Parameter set changeover

As supplied:

Jogging

The “Jogging” function switches the system to the “Jogging demand” on the demand
channel (see Application parameters).