Commissioning

Important controller codes

7

l

118

EDK82MV371 DE/EN/FR 7.0

Code

Possible settings

IMPORTANT

No.

Name

Lenze

Selection

C0002
*

s
uSEr

Parameter
set
managemen
t

0

0

Ready

PAR1 ... PAR4:

l

Parameter sets of the
controller

l

PAR1 ... PAR4 also
contain the
parameters for the
function modules
standard I/O,
application I/O, AS
interface, system bus
(CAN)

FPAR1:

l

Module−specific
parameter set of the
fieldbus function
modules INTERBUS,
PROFIBUS−DP,
LECOM−B,
DeviceNet/CANopen

l

FPAR1 is saved in the
function module

Restoring
the delivery
status

1

Lenze setting

ð PAR1

Restore the delivery
status in the parameter
set selected

2

Lenze setting

ð PAR2

3

Lenze setting

ð PAR3

4

Lenze setting

ð PAR4

31

Lenze setting

ð FPAR1

Restore the delivery
status in the fieldbus
function module

61

Lenze setting

ð PAR1 + FPAR1

Restore the delivery
status in the selected
parameter set of the
controller and in the
fieldbus function module

62

Lenze setting

ð PAR2 + FPAR1

63

Lenze setting

ð PAR3 + FPAR1

64

Lenze setting

ð PAR4 + FPAR1

C0002
*

s
uSEr

(Contin
uation)

Transferring
parameter
sets with the
keypad

By means of the keypad
you can transfer the
parameter sets to other
controllers.
During the transmission
the access to the
parameters via other
channels is inhibited!

Keypad

ð controller

Overwrite all available
parameter sets
(PAR1 ... PAR4, if required
FPAR1) with the
corresponding data of
the keypad

70

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen

10

with all other function modules