Commissioning

Important controller codes

7

l

121

EDK82MV371 DE/EN/FR 7.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0007

v
uSEr

Fixed
configuratio
n digital
inputs

Change of C0007 is
copied into the
corresponding subcode
of C0410. Free
configuration in C0410
sets C0007 = 255!

0

E4

E3

E2

E1

l

CW/CCW = clockwise
rotation/counter−cloc
kwise rotation

l

DCB = DC injection
brake

l

QSP = quickstop

l

PAR = change over
parameter set
(PAR1

ó PAR2)

– PAR1 = LOW,

PAR2 = HIGH

– The terminal in

PAR1 and PAR2
has to be assigned
with the "PAR"
function.

– Only use

configurations
with "PAR" if
C0988 = 0

l

TRIP−Set = external
error

0

CW/CCW

DCB

JOG2/3

JOG1/3

1

CW/CCW

PAR

JOG2/3

JOG1/3

2

CW/CCW

QSP

JOG2/3

JOG1/3

3

CW/CCW

PAR

DCB

JOG1/3

4

CW/CCW

QSP

PAR

JOG1/3

5

CW/CCW

DCB

TRIP−Set

JOG1/3

6

CW/CCW

PAR

TRIP−Set

JOG1/3

7

CW/CCW

PAR

DCB

TRIP−Set

8

CW/CCW

QSP

PAR

TRIP−Set

9

CW/CCW

QSP

TRIP−Set

JOG1/3

10

CW/CCW

TRIP−Set

UP

DOWN

C0007

v
uSEr

(Contin
uation)

E4

E3

E2

E1

l

Selection of
fixed
setpoints

JOG1/3 JOG2/
3
LOW

LOW

HIGH

LOW

LOW

HIGH

HIGH

HIGH

Active
C0046
JOG1
JOG2
JOG3

11

CW/CCW

DCB

UP

DOWN

12

CW/CCW

PAR

UP

DOWN

13

CW/CCW

QSP

UP

DOWN

14

CCW/QS

P

CW/QSP

DCB

JOG1/3

15

CCW/QS

P

CW/QSP

PAR

JOG1/3

16

CCW/QS

P

CW/QSP

JOG2/3

JOG1/3

17

CCW/QS

P

CW/QSP

PAR

DCB

18

CCW/QS

P

CW/QSP

PAR

TRIP−Set

19

CCW/QS

P

CW/QSP

DCB

TRIP−Set