Commissioning
Important controller codes
l
121
EDK82MV371 DE/EN/FR 7.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0007
v
uSEr
Fixed
configuratio
n digital
inputs
Change of C0007 is
copied into the
corresponding subcode
of C0410. Free
configuration in C0410
sets C0007 = 255!
0
E4
E3
E2
E1
l
CW/CCW = clockwise
rotation/counter−cloc
kwise rotation
l
DCB = DC injection
brake
l
QSP = quickstop
l
PAR = change over
parameter set
(PAR1
ó PAR2)
– PAR1 = LOW,
PAR2 = HIGH
– The terminal in
PAR1 and PAR2
has to be assigned
with the "PAR"
function.
– Only use
configurations
with "PAR" if
C0988 = 0
l
TRIP−Set = external
error
0
CW/CCW
DCB
JOG2/3
JOG1/3
1
CW/CCW
PAR
JOG2/3
JOG1/3
2
CW/CCW
QSP
JOG2/3
JOG1/3
3
CW/CCW
PAR
DCB
JOG1/3
4
CW/CCW
QSP
PAR
JOG1/3
5
CW/CCW
DCB
TRIP−Set
JOG1/3
6
CW/CCW
PAR
TRIP−Set
JOG1/3
7
CW/CCW
PAR
DCB
TRIP−Set
8
CW/CCW
QSP
PAR
TRIP−Set
9
CW/CCW
QSP
TRIP−Set
JOG1/3
10
CW/CCW
TRIP−Set
UP
DOWN
C0007
v
uSEr
(Contin
uation)
E4
E3
E2
E1
l
Selection of
fixed
setpoints
JOG1/3 JOG2/
3
LOW
LOW
HIGH
LOW
LOW
HIGH
HIGH
HIGH
Active
C0046
JOG1
JOG2
JOG3
11
CW/CCW
DCB
UP
DOWN
12
CW/CCW
PAR
UP
DOWN
13
CW/CCW
QSP
UP
DOWN
14
CCW/QS
P
CW/QSP
DCB
JOG1/3
15
CCW/QS
P
CW/QSP
PAR
JOG1/3
16
CCW/QS
P
CW/QSP
JOG2/3
JOG1/3
17
CCW/QS
P
CW/QSP
PAR
DCB
18
CCW/QS
P
CW/QSP
PAR
TRIP−Set
19
CCW/QS
P
CW/QSP
DCB
TRIP−Set