Fault messages

8

l

135

EDK82MV371 DE/EN/FR 7.0

Remedy

Cause

Fault

PC

1)

Keypad

OH3

a

53

PTC monitoring
(TRIP)
(display when
C0119 = 1 or 4)

Motor too hot due to
impermissible high currents
or frequent and too long
acceleration processes

Check drive dimensioning

No PTC connected

Connect PTC or switch off
monitoring

OH4

a

54

Controller
overtemperature

Controller is too hot inside

l

Reduce controller load

l

Improve cooling

l

Check fan in the controller

OH51

203

PTC monitoring
(display when
C0119 = 2 or 5)

Motor too hot due to
impermissible high currents
or frequent and too long
acceleration processes

Check drive dimensioning

No PTC connected

Connect PTC or switch off
monitoring

OU

c

DC−bus
overvoltage
(message or TRIP
configurable in
C0310)

Mains voltage is too high

Check supply voltage

OUE

a

22

Braking operation

l

Increase deceleration times

l

For operation with an
external brake resistor:
– Check dimensioning,

connection and supply
cable of the brake resistor

– Increase deceleration

times

Earth leakage at motor end

Check motor supply cable and
motor for earth fault
(disconnect motor from the
inverter)

Pr

a

75

Faulty parameter
transfer via
keypad

All parameter sets are
defective

Before enabling the controller,
repeat the data transfer or load
the Lenze setting

Pr1

a

72

Faulty PAR1
transfer via
keypad

Parameter set 1 is defective

Pr2

a

73

Faulty PAR2
transfer via
keypad

Parameter set 2 is defective

Pr3

a

77

Faulty PAR3
transfer via
keypad

Parameter set 3 is defective

Pr4

a

78

Faulty PAR4
transfer via
keypad

Parameter set 4 is defective