Mechanical installation
Motor mounting
l
98
EDK82MV371 DE/EN/FR 7.0
Preparation
Fig. 4−3
1a
1a
3.4 Nm
30 lb-in
1a
4 ×
M20
M16
2 ×
A
5mm
68mm
68mm
B
2
A
8200mot053
Motor preparation:
l
Remove terminal box seal
0 and motor terminal board.
l
If necessary, extend the motor cable.
Mount the carrier housing to the motor:
l
If required, use the distance and wall mounting plate (2) and the terminal box seal
0 .
l
The mounting and fixing must ensure a permanently tight mechanical connection, for instance by
using serrated lock washers
1.
Perfect sealing is required to ensure IP65 enclosure.