Mechanical installation

Motor mounting

4

l

98

EDK82MV371 DE/EN/FR 7.0

Preparation

Fig. 4−3

1a

1a

3.4 Nm

30 lb-in

1a

4 ×

M20

M16

2 ×

A

5mm

68mm

68mm

B

2

A

8200mot053

Motor preparation:

l

Remove terminal box seal

0 and motor terminal board.

l

If necessary, extend the motor cable.

Mount the carrier housing to the motor:

l

If required, use the distance and wall mounting plate (2) and the terminal box seal

0 .

l

The mounting and fixing must ensure a permanently tight mechanical connection, for instance by
using serrated lock washers

1.

Perfect sealing is required to ensure IP65 enclosure.