Mechanical installation

motec with motor or geared motor

4

l

91

EDK82MV371 DE/EN/FR 7.0

EMC−compliant wiring
Conditions for trouble−free operation:

ƒ Except for the mains cable, use shielded cables only.
ƒ Carefully connect the shielding to PE.
ƒ Connect motor and mains PE conductors to separate PE terminals.

A

E

B

X1

C

8200mot151

D

F

Shield connection:
1. Prepare the cable

2. Insert the cable tie

3. Lay the cable into the

cable tie and tighten it.
The shield must be
tightly connected to
the shield sheet.

0

Mains cable L1, N, PE or. L1, L2, PE

1

PE connection for mains cable

2

PE connection for motor

3

Shielded control cable

4

Shield connection, control cables; fix the shield tightly to the sheet with the cable tie

5

Function module

X1

Terminal strip mains connection

PES

HF−shield termination by large surface connection to PE