Commissioning

Important controller codes

7

l

127

EDK82MV371 DE/EN/FR 7.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0148
*

s

Identifying
motor data

0

0

Ready

Only when the motor is
cold!
1. Inhibit controller,

wait until drive is at
standstill

2. Enter the correct

values from the
motor nameplate in
C0087, C0088, C0089,
C0090, C0091

3. Set C0148 = 1,

confirm with

v

4. Enable controller:

The identification
– starts,

c goes

out

– the motor

"whistles" faintly
but it does not
rotate!

– takes approx. 30 s
– is completed when

c is lit again

5. Inhibit controller

1

Start identification

l

V/f rated frequency (C0015), slip
compensation (C0021) and motor
stator inductance (C0092) are
calculated and saved

l

The motor stator resistance
(C0084) = total resistance of the
motor cable and motor is
measured and saved