Technical data – Lenze E82MVxxx 2Bxxx User Manual
Page 85
Technical data
General data and operating conditions
l
85
EDK82MV371 DE/EN/FR 7.0
EMC
Complies with requirements according to EN 61800−3
Noise emission
l
cable−guided
IEC/EN 61800−3
Motor mounting:
Compliance with limit class C1
Wall mounting:
– Compliance with the limit class C1 when shielded
motor cables up to a length of 1 m are used
– Compliance with the limit class C2 when shielded
motor cables up to a length of 10 m are used
Noise immunity
Requirements
Standard
Severity
ESD
IEC/EN 61000−4−2
8 kV with air discharge,
4 kV with contact discharge
Cable−guided high
frequency
IEC/EN 61000−4−6
150 kHz ... 80 MHz,
10 V/m 80 % AM (1 kHZ)
Burst
IEC/EN 61000−4−4
3/4, i.e. 2 kV / 5 kHz
Surge (surge
voltage on mains
cable)
IEC/EN 61000−4−5
3, i.e. 1.2 / 50
ms,
1 kV phase/phase, 2 kV
phase/PE
Operation on public
supply systems
EN 61000−3−2
Limitation of harmonic
currents
Total power on the mains
Compliance with the
requirements
1)
0.25 kW ... 0.75 kW
With mains choke
> 1 kW
No measures required
1)
The additional measures mentioned effect that solely the controllers meet the requirements of
EN 61000−3−2. The machine/system manufacturer is responsible for compliance with the
requirements of the machine/system!