Commissioning, V user, User – Lenze E82MVxxx 2Bxxx User Manual
Page 123
![background image](/manuals/566251/123/background.png)
Commissioning
Important controller codes
l
123
EDK82MV371 DE/EN/FR 7.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0007
v
uSEr
(Contin
uation)
E4
E3
E2
E1
41
JOG1/3
DCB
TRIP−Set
DFIN1−ON
42
QSP
DCB
TRIP−Set
DFIN1−ON
43
CW/CCW
QSP
TRIP−Set
DFIN1−ON
44
UP
DOWN
PAR
DFIN1−ON
45
CW/CCW
QSP
PAR
DFIN1−ON
46
H/Re
PAR
QSP
JOG1/3
47
CW/QSP
CCW/QS
P
H/Re
JOG1/3
48
PCTRL1−
OFF
DCB
PCTRL1−
I−OFF
DFIN1−ON
49
PCTRL1−
OFF
JOG1/3
QSP
DFIN1−ON
50
PCTRL1−
OFF
JOG1/3
PCTRL1−
I−OFF
DFIN1−ON
51
DCB
PAR
PCTRL1−
I−OFF
DFIN1−ON
255
Free configuration in C0410
Read only
Do not change C0007
since settings in C0410
may get lost
C0010
uSEr
Minimum
output
frequency
0.00
0.00
à
14.5 Hz
{0.02
Hz}
650.00
l
C0010 not effective
in the case of bipolar
setpoint selection
(−10 V ... + 10 V)
l
C0010 only limits the
analog input 1
l
In the case of a max.
output frequency >
50 Hz the switching
threshold of the auto
DCB in C0019 has to
be increased.
l
From software 3.5: If
C0010 > C0011, the
drive does not start
when controller
enable is set.
à
Speed setting range 1
: 6 for Lenze geared
motors: For operation
with Lenze geared
motors has to be set
necessarily.
C0011
uSEr
Maximum
output
frequency
50.00 7.50
à
87 Hz
{0.02
Hz}
650.00