Troubleshooting and fault elimination – Lenze E82MVxxx 2Bxxx User Manual
Page 133
![background image](/manuals/566251/133/background.png)
Troubleshooting and fault elimination
Fault messages
l
133
EDK82MV371 DE/EN/FR 7.0
Remedy
Cause
Fault
PC
1)
Keypad
ce6
a
67
System bus
(CAN) function
module on FIF
has the
"Warning" or
"BUS−OFF"
status
(configurable in
C0126)
CAN controller reports
"Warning" or "BUS−OFF"
status
l
Check bus termination
l
Check shield connection of
the cables
l
Check PE connection
l
Check bus load, reduce the
baud rate, if necessary
ce7
a
68
Communication
error during
remote
parameterisatio
n via system bus
(C0370)
(configurable in
C0126)
Node does not respond or is
not available
l
Check bus termination
l
Check shield connection of
the cables
l
Check PE connection
l
Check bus load, reduce the
baud rate, if necessary
For operation with
application I/O:
Parameter set change−over
has been parameterised
incorrectly
The "parameter set
change−over" signal (C0410/13,
C0410/14) must be connected
to the same source in all
paramerter sets
EEr
a
91
External fault
(TRIP−SET)
A digital signal assigned to
the TRIP−Set function is
activated
Check external encoder
ErP0
...
ErP19
a
−
Communication
abort between
keypad and
standard device
Various
Contact Lenze
FAn1
a
95
Fan failure
(only 8200
motec
3 ... 7.5 kW)
TRIP or warning
configurable in
C0608
Fan is defective
Replace fan
FAn1
−
Fan is not connected
Connect fan
Check wiring
H05
a
105
Internal fault
Contact Lenze
id1
a
140
Faulty parameter
identification
Motor is not connected
Connect motor
LP1
a
32
Motor phase
error
(display when
C0597 = 1)
l
Failure of one/several
motor phases
l
Motor current is too low
l
Check motor supply cables
l
Check V
min
boost,
l
Connect motor with a
corresponding power or
adapt motor with C0599
LP1
182
Motor phase
error
(Display when
C0597 = 2)