Product Overview

1-7

Factory Installed Options

Optional HOA Keypad Configuration (Bulletin 280/281 only)

The ArmorStart offers two optional factory-installed Hand/Off/Auto
(HOA) configurations: Standard and Forward/Reverse HOA.

Figure 1.4 Optional HOA Configuration

Optional HOA Selector Keypad with Jog Function (Bulletin 284
only)

The HOA Selector Keypad with Jog Function allows for local start/
stop control with capabilities to jog in forward/reverse motor
directions.

Figure 1.5 Optional HOA with Jog Function Configuration

Source Brake Contactor (Bulletins 284 only)

An internal contactor is used to switch the electromechanical motor
brake on/off. The motor brake is powered from the main power
circuit. A customer-accessible 3.0 A fuse is provided to protect the
brake cable. A 3 meter, 3-pin cable for connection to the motor brake
is provided as standard when the option is selected.

EMI Filter (Bulletin 284 only)

The EMI Filter option is required if the Bulletin 284 ArmorStart
Distributed Motor Controller must be CE-compliant. If the EMI Filter
is selected, a 3 meter shielded 4-conductor cordset is provided as
standard. This option is only available with sensorless vector control.