Bulletin 284 Programmable Parameters for Sensorless Vector Controllers

Output Power
The output power present at T1, T2, and T3.

Parameter Number

122

Access Rule

GET

Data Type

UINT

Group

Display Group

Units

Minimum Value

0.00

Maximum Value

Drive rated power X 2

Default Value

Read Only

Output Power Fctr
The angle in electrical degrees between motor voltage and current.

Parameter Number

123

Access Rule

GET

Data Type

UINT

Group

Display Group

Units

0.1

°

Minimum Value

0.0

°

Maximum Value

180.0

°

Default Value

Read Only

Drive Temp
Present operating temperature of the drive power section.

Parameter Number

124

Access Rule

GET

Data Type

UINT

Group

Display Group

Units

1

°C

Minimum Value

0

Maximum Value

120

Default Value

Read Only

Counter Status
The current value of the counter when counter is enabled.

Parameter Number

125

Access Rule

GET

Data Type

UINT

Group

Display Group

Units

1

Minimum Value

0

Maximum Value

9999

Default Value

Read Only

Timer Status
The current value of the timer when timer is enabled.

Parameter Number

126

Access Rule

GET

Data Type

UINT

Group

Display Group

Units

0.1 sec

Minimum Value

0

Maximum Value

9999

Default Value

Read Only