Bulletin 284 Programmable Parameters for Sensorless Vector Controllers

4-25

Basic Program Group

Stp Logic Status
When Parameter 138 (Speed Reference) is set to 6 Stp Logic, this parameter will
display the current step of step logic as defined by Parameters 240…247 (Stp
Logic X).

Parameter Number

128

Access Rule

GET

Data Type

UINT

Group

Display Group

Units

1

Minimum Value

0

Maximum Value

8

Default Value

Read Only

Torque Current
The current value of the motor torque current.

Parameter Number

129

Related Parameters

Access Rule

GET

Data Type

UINT

Group

Display Group

Units

0.01

Minimum Value

0.00

Maximum Value

Drive Rated Amps x 2

Default Value

Read Only

Motor NP Volts

Set to the motor name plate rated volts.

Parameter Number

131

Related Parameters

104, 184, 185…187

Access Rule

GET/SET

Data Type

UINT

Group

Basic Program

Units

1V AC

Minimum Value

20

Maximum Value

240V, 460V, or 600V AC

Default Value

Based on Drive Rating

Motor NP Hertz
Set to the motor nameplate rated frequency.

Parameter Number

132

Related Parameters

184, 185…187, and 190

Access Rule

GET/SET

Data Type

UINT

Group

Basic Program

Units

1 Hz

Minimum Value

15

Maximum Value

400

Default Value

60 Hz

Stop drive before changing this parameter.

Stop drive before changing this parameter.