background image

Bulletin 284 CIP Information

C-13

Connection Object — CLASS CODE 0x0005

No class attributes are supported for the Connection Object.

Multiple instances of the Connection Object are supported, Instances
1, 2, and 4 from the Group 2 predefined master/slave connection set,
Instances 5 and 6 are available through explicit UCMM connections.

Instance 1 is the Predefined Group 2 Connection Set Explicit
Message Connection. The following Instance 1 attributes is supported

Table C.34 Connection Object Instance 1 Attributes:

Attribute

ID

Access

Rule

Name

Data
Type

Value

1

Get

State

USINT

0 = non-existent
1 = configuring
3 = established
4 = timed out

2

Get

Instance Type

USINT

0 = Explicit Message

3

Get

Transport Class Trigger

USINT

0x83 — Server, Transport
Class 3

4

Get

Produced Connection ID

UINT

10xxxxxx011
xxxxxx = node address

5

Get

Consumed Connection ID

UINT

10xxxxxx100
xxxxxx = node address

6

Get

Initial Comm Characteristics

USINT

0x22

7

Get

Produced Connection Size

UINT

0x61

8

Get

Consumed Connection Size

UINT

0x61

9

Get/Set

Expected Packet Rate

UINT

in milliseconds

12

Get

Watchdog Action

USINT

01 = auto delete
03 = deferred delete

13

Get

Produced Connection Path
Length

UINT

0

14

Get

Produced Connection Path

Empty

15

Get

Consumed Connection Path
Length

UINT

0

16

Get

Consumed Connection Path

Empty