Rockwell Automation 284D ArmorStart - Safety Version - User Manual User Manual

Page 80

Advertising
background image

4-10

Bulletin 284 Programmable Parameters for Sensorless Vector Controllers

Produced I/O Size
This parameter maps to the Scanners Rx Size.

Parameter Number

18

Access Rule

GET

Data Type

USINT

Group

DeviceNet

Units

Minimum Value

0

Maximum Value

8

Default Value

4

Starter COS Mask
This parameter allows the installer to define the change-of-state conditions that will
result in a change-of-state message being produced.

Parameter Number

19

Access Rule

GET/SET

Data Type

WORD

Group

DeviceNet

Units

Minimum Value

0

Maximum Value

16383

Default Value

16383

Bit

Function

13

12

11

10

9

8

7

6

5

4

3

2

1

0

X

Tripped

X

Warning

X

Running Fwd

X

Running Rev

X

Ready

X

Net Ctl Status

X

Net Ref Status

X

At Reference

X

User Input 1

X

User Input 2

X

User Input 3

X

User Input 4

X

HOA Status

X

140M On

Advertising