Rockwell Automation 284D ArmorStart - Safety Version - User Manual User Manual

Page 174

Advertising
background image

9-10

ArmorStart® ZIP Configuration

And assuming that the 1799-ZCIO module is producing the following
data:

The above configuration results in the following DeviceLogix ZIP
Data Table mapping

Instance 163 Standard Produced Starter with Network Outputs and ZIP CCV

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

1

Ready

Running Rev Running Fwd

Warning

Tripped

2

140M On

HOA

User In 4

User In 3

User In 2

User In 1

3

Net Out 8

Net Out 7

Net Out 6

Net Out 5

Net Out 4

Net Out 3

Net Out 2

Net Out 1

4

Net Out 15

Net Out 14

Net Out 13

Net Out 12

Net Out 11

Net Out 10

Net Out 9

5

Device Value Key (low)

6

Device Value Key (high)

1799-ZCIO Produced Assembly

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

1

Input 7

Input 6

Input 5

Input 4

Input 3

Input 2

Input 1

Input 0

2

Logic Ena

Input 9

Input 8

3

Output 7

Output 6

Output 5

Output 4

Output 3

Output 2

Output 1

Output 0

4

Output 9

Output 8

5

Net Out 7

Net Out 6

Net Out 5

Net Out 4

Net Out 3

Net Out 2

Net Out 1

Net Out 0

6

ZIP CCV (Low)

7

ZIP CCV (High)

Advertising