Module placement – Rockwell Automation 1715-OF8I Redundant I/O System User Manual User Manual

Page 55

Advertising
background image

Rockwell Automation Publication 1715-UM001C-EN-P - March 2014

55

Installation Instructions

Chapter 2

Module Placement

A general overview of a typical redundant I/O system layout is shown here.

The adapter and base units are DIN-rail mounted and connections are chained

together from left to right.

IO BASE

1715-A310

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTA

Dual.

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTA

Dual.

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTA

Dual.

Ethernet 1
Ethernet 2

Reset

Ethernet 1
Ethernet 2

Reset

Channel 00
Channel 01
Channel 02
Channel 03
Channel 04
Channel 05
Channel 06
Channel 07

Channel 08
Channel 09
Channel 10
Channel 11
Channel 12
Channel 13
Channel 14
Channel 15

IO BASE

1715-A310

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTA

Dual.

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTA

Dual.

CH1

CH1

CH1

CH1

CH1

CH1

CH1

CH1

TERMINAL IDENTITY

AOTA

Dual.

Module Status

Redundancy Status

Network Status

Rack Status

Module Status

Redundancy Status

Network Status

Rack Status

Healthy

Ready

Run

Healthy

Ready

Run

Healthy

Ready

Run

Healthy

Ready

Run

Healthy

Ready

Run

Healthy

Ready

Run

Channel 00
Channel 01
Channel 02
Channel 03
Channel 04
Channel 05
Channel 06
Channel 07

Channel 08
Channel 09
Channel 10
Channel 11
Channel 12
Channel 13
Channel 14
Channel 15

Channel 00
Channel 01
Channel 02
Channel 03
Channel 04
Channel 05
Channel 06
Channel 07

Channel 00
Channel 01
Channel 02
Channel 03
Channel 04
Channel 05
Channel 06
Channel 07

Channel 08
Channel 09
Channel 10
Channel 11
Channel 12
Channel 13
Channel 14
Channel 15

Channel 00
Channel 01
Channel 02
Channel 03
Channel 04
Channel 05
Channel 06
Channel 07

Channel 08
Channel 09
Channel 10
Channel 11
Channel 12
Channel 13
Channel 14
Channel 15

Channel 00
Channel 01
Channel 02
Channel 03
Channel 04
Channel 05
Channel 06
Channel 07

1

4

2

3

5

6

7

8

9

10

11

32065-M

12

13

TIP

This illustration is only an example and is for illustrative purposes only.

Item

Description

1

Adapter base unit

2

Adapter A module

3

Adapter B module

4

I/O base unit

5

Simplex I/O module

6

Duplex I/O module - first in pair

7

Duplex I/O module - second in pair

8

I/O base unit

9

Simplex I/O module

10

Duplex I/O module - first in pair

11

Duplex I/O module - second in pair

12

Power connections

13

Ethernet connections

Advertising