Formatting and interpreting data blocks chapter 7 – Rockwell Automation 1771-QC , D17716.5.25 SER/B SERVO POS User Manual
Page 102
![background image](/manuals/579607/102/background.png)
Formatting and Interpreting Data Blocks
Chapter 7
7Ć20
Figure 7.10
Address Pointer Words
17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00
Parameter Block Pointer
Word 2
Data table address of parameter
block, BCD format
17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00
Command Block Pointer
Word 3
Data table address of command
block, BCD format
17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00
Axis 1 Moveset Block Pointer
Word 4
Data table address of first moveset
block to be transferred for axis 1,
BCD format.
17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00
Axis 2 Moveset Block Pointer
Word 5
Data table address of first moveset
block to be transferred for axis 2,
BCD format.
17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00
Axis 3 Moveset Block Pointer
Word 6
11032
Data table address of first moveset
block to be transferred for axis 3,
BCD format.