Rockwell Automation 1771-QC , D17716.5.25 SER/B SERVO POS User Manual

Page 76

Advertising
background image

Installing the Assembly

Chapter 6

6Ć26

Connecting the Tachometer

Figure 6.15 shows details of how to connect the tachometer. Follow these
steps:

Figure 6.15

Connection Details for Tachometer

1
2
3
4
5
6
7
8
9

10
11
12

Right Wiring Arm

of 1771 - ES Expander

Servo Drive

High

(+)

Low

(-)

Tach

27K

High

Low

50V Max

at Terminals

12025

1.

Connect the tachometer directly to the servo drive.

2.

Connect the tachometer signal at the servo drive to the right wiring
arm of the 1771-ES expander. This allows the 1771-ES expander to
detect loss of tachometer feedback at the servo drive. Limit the
voltage at the terminals to 50V maximum. Tachometers typically
generate much larger voltages than 50V at high speed. Therefore,
you must drop the voltage thru a voltage divider.

3.

Unless you have access to a voltage divider in the servo drive, place
a 27k ohms 1/4 Watt potentiometer between the servo drive and
terminal 11 of the 1771-ES expander.

4.

Set the potentiometer for maximum resistance until you perform the
integration procedures (chapter 9).

Advertising