Formatting and interpreting data blocks chapter 7 – Rockwell Automation 1771-QC , D17716.5.25 SER/B SERVO POS User Manual

Page 96

Advertising
background image

Formatting and Interpreting Data Blocks

Chapter 7

7Ć14

Figure 7.6

Position/ Following error/ Diagnostic Words Ć with Position or Following error Selected

07 06 05 04 03 02 01 00

07 06 05 04 03 02 01 00

Sign:

0 = +

1 = -

inch decimal point

metric

17 16 15 14 13 12 11 10

17 16 15 14 13 12 11 10

Position or Following Error (Most Significant Word)

0

Position or Following Error (Least Significant Word)

BCD position or following error value

(999.9999 inches or 19999.99 mm

max)

Most significant digits

Least significant digits

11055

0

Word 5 (Axis 1)

Word 9 (Axis 2)

Word 13 (Axis 3)

Word 6 (Axis 1)

Word 10 (Axis 2)

Word 14 (Axis 3)

decimal

point

Turn off bit 11 and turn on bit 15 to display the following error as shown
in Figure 7.6. The maximum value is 999.9999 inch or 19999.999 mm.
If the axis exceeds the maximum, it displays the maximum.

Turn on bit 11 to display the diagnostic status as shown in Figure 7.7.

Advertising