Parameter block appendix c – Rockwell Automation 1771-QC , D17716.5.25 SER/B SERVO POS User Manual

Page 235

Advertising
background image

Parameter Block

Appendix C

CĆ4

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

High Jog Rate

Word 13 (Axis 1)

Word 32 (Axis 2)

Word 51 (Axis 3)

Multiplier

001 = x 10

-1

000 = x 10

0

010 = x 10

100 = x 10

110 = x 10

111 = x 10

1
2
3

4

inch

metric

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

Low Jog Rate

Word 14 (Axis 1)

Word 33 (Axis 2)

Word 52 (Axis 3)

Multiplier

001 = x 10

-1

000 = x 10

0

010 = x 10

100 = x 10

110 = x 10

111 = x 10

1
2
3

4

decimal

point

decimal

point

inch

metric

decimal

point

point

decimal

This BCD value (0.999 ipm or

19.99 mmpm max) times the

multiplier is the high jog rate. It must

not be higher than the rapid traverse

rate.

This BCD value (0.999 ipm or

19.99 mmpm max) times the

multiplier is the low jog rate. It must

be lower than the high jog rate.

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

% Excess Following Error (MSD), +D/A Voltage

Word 15 (Axis 1)

Word 34 (Axis 2)

Word 53 (Axis 3)

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

% Excess Following Error (LSD), -D/A Voltage

Word 16 (Axis 1)

Word 35 (Axis 2)

Word 54 (Axis 3)

Most significant

digit of excess

following error

percentage, BCD

format.

Maximum + D/A voltage

(analog output voltage),

BCD format. For +10.0V,

program 000.

Least significant

digit of excess

following error

percentage, BCD

format.

Maximum Ć D/A voltage

(analog output voltage),

BCD format. For Ć10.0V,

program 000.

Excess following error percent should be greater than or equal to 6%.

The value entered here is the percent above rapid traverse following

error at which Emergency Stop is to occur.

Advertising