Formatting and Interpreting Data Blocks

Chapter 7

7Ć45

101 (axis 2), or 110 (axis 3) that is the moveset that you want to
normally execute first.

2.

The moveset that contains the escape move must contain no other
moves. The escape moveset thus contains only one move, and a next
moveset pointer that identifies the moveset that you want to normally
execute first.

Figure 7.32

Moveset Profiles Ć Showing Alternating Moveset IDs

Rate

Axis 1

Moveset Block 1

ID 001

Moveset Block 2

Moveset Block 3

Position

NOTE: Moveset block ID is in bits 12, 11, and 10 of moveset control word.

11016

Axis 2

Axis 3

Rate

Rate

ID 100

ID 001

Moveset Block 1

ID 010

Moveset Block 2

Moveset Block 3

ID 101

ID 010

Moveset Block 1

ID 011

Moveset Block 2

Moveset Block 3

ID 110

ID 011

Position

Position

3.

The escape moveset block cannot be executed as part of a sequence
of moveset blocks.