Formatting and Interpreting Data Blocks

Chapter 7

7Ć30

D/A = maximum D/A voltage

IG = initial gain

These formulas include an allowance for a 127% feedrate override factor.
These formulas apply to both ipm and mmpm.

Jog Rate

The high and log jog rate words (Figure 7.20) specify the speeds at which
you can jog the axis. You can jog the axis only in manual mode. Program
the values in BCD format. The operator can select jog speed (high or
low) by controlling the jog rate select bit in the command block.

Figure 7.20

Jog Rate Words

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

High Jog Rate

Word 13 (Axis 1)

Word 32 (Axis 2)

Word 51 (Axis 3)

Multiplier

001 = x 10

-1

000 = x 10

0

010 = x 10

100 = x 10

110 = x 10

111 = x 10

1
2
3

4

inch

metric

This BCD value (0.999 ipm or

19.99 mmpm max) times the

multiplier is the high jog rate. It must

not be higher than the rapid traverse

rate.

11042

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

Low Jog Rate

Word 14 (Axis 1)

Word 33 (Axis 2)

Word 52 (Axis 3)

Multiplier

001 = x 10

-1

000 = x 10

0

010 = x 10

100 = x 10

110 = x 10

111 = x 10

1
2
3

4

This BCD value (0.999 ipm or

19.99 mmpm max) times the

multiplier is the low jog rate. It must

be lower than the high jog rate.

decimal

point

decimal

point

inch

metric

decimal

point

point

decimal