Troubleshooting

Chapter 10

10Ć5

Turn on bit 11 to display the diagnostic status as shown in Figure 10.4.

Also, this diagnostic status displays automatically when the 1771-M3
controller detects an error in the parameter block immediately after
power-up or an invalid ID in a command block. The diagnostic status
displays automatically in that case because the error prevents you from
selecting it thru the command block.

Figure 10.4

Position/FollowingĆError/Diagnostic Words Ć with Diagnostic Selected

17

16

15

14

13

12

11

10

07

06

05

04

03

02

01

00

Word pointer - This BCD

number tells you which

word is in error within

the block.

Error code - This BCD

number references the

error listed in Table 10.A.

First Diagnostic Word

Second Diagnostic Word

17

16

15

14

13

12

11

10

07

06

05

04

03

02

01

00

Block pointer - This BCD number is the

address of the block that is in error.

The second diagnostic word is the block pointer. The block pointer is a
BCD number that indicates the starting address of the block in error. The
1771-M3 controller gets these block pointers from the block pointers you
enter into the parameter block or the moveset block.

The high byte (bits 10 thru 17) of the first diagnostic word is the word
pointer. The word pointer is a BCD number (1 thru 64) that indicates
which word is in error within the block.