Formatting and Interpreting Data Blocks

Chapter 7

7Ć33

Figure 7.22

Home Position Words

07 06 05 04 03 02 01 00

07 06 05 04 03 02 01 00

Sign:

0 = +

1 = -

BCD home position value

(999.9999 inches or 19999.99 mm

max)

Most significant digits

Least significant digits

11044

Word 17 (Axis 1)

Word 36 (Axis 2)

Word 55 (Axis 3)

External

synchronization of

feedrate overide

0 = disable

1 = enable

LossĆofĆfeedback

detection

0 = disable

1 = enable

inch

metric

17 16 15 14 13 12 11 10

17 16 15 14 13 12 11 10

Word 18 (Axis 1)

Word 37 (Axis 2)

Word 56 (Axis 3)

Most Significant Home Position

Home Position (Least Significant Word)

decimal

point

decimal

point

inch

decimal

point

LossĆofĆFeedback Detection Enable

Turn bit 15 off until you complete the open-loop and closed-loop axis
integration procedures (chapter 9).

Then turn on bit 15 of the most significant home position word to enable
the loss-of-feedback detection feature of the 1771-ES expander.

WARNING: Once you have completed the axis integration
procedures, never turn this bit off. Without loss-of-feedback
detection, if encoder or tachometer feedback is lost, unexpected
axis motion can occur, resulting in damage to equipment and/or
injury to personnel.

External Synchronization of Feedrate Override

Turn on bit 16 of the most significant home position word to have the
1771-ES expander recognize the feedrate override enable input
(Figure 7.22).