Parameter block appendix c – Rockwell Automation 1771-QC , D17716.5.25 SER/B SERVO POS User Manual

Page 234

Advertising
background image

Parameter Block

Appendix C

CĆ3

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

Encoder Lines

Word 8 (Axis 1)

Word 27 (Axis 2)

Word 46 (Axis 3)

The value of this word times the mulitplier

specified by bit 15 of the next word must equal

the actual number of encoder lines, BCD

format. For 10,000, program 0000.

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

Feedback Multiplier, Encoder Lines Multiplier, Loss-of-marker, Initial Gain

Word 9 (Axis 1)

Word 28 (Axis 2)

Word 47 (Axis 3)

Feedback

Multiplier

01 = x 1

10 = x 2

00 = x 4

Encoder

Lines

Multiplier

0 = x 1

1 = x 4

(See preceding

word.)

Loss-of-marker

detection

0 = disabled

1 = enabled

Initial Gain, ipm/mil or

mmpm/mil, BCD format.

(1 mil = 0.001 inch or 0.001

millimeter.)

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

Gain Break Speed

Word 10 (Axis 1)

Word 29 (Axis 2)

Word 48 (Axis 3)

Multiplier

001 = x 10

-1

000 = x 10

0

010 = x 10

100 = x 10

110 = x 10

111 = x 10

1
2
3

4

inch

metric

decimal

point

decimal

point

This BCD value (0.999 ipm or

19.99 mmpm max) times the

multiplier is the gain break speed.

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

Word 11 (Axis 1)

Word 30 (Axis 2)

Word 49 (Axis 3)

This BCD value (99 max) times 2

is the inĆposition band in

increments of feedback

resolution.

Gain reduction factor

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

Rapid Traverse Rate

Word 12 (Axis 1)

Word 31 (Axis 2)

Word 50 (Axis 3)

Multiplier

001 = x 10

-1

000 = x 10

0

010 = x 10

100 = x 10

110 = x 10

111 = x 10

1
2
3

4

inch

metric

decimal

point

decimal

point

This BCD value (0.999 ipm or

19.99 mmpm max) times the

multiplier is the rapid traverse rate.

Advertising