Rockwell Automation 1794-APBDPV1 FLEX I/O PROFIBUS Adapter User Manual User Manual

Page 48

Advertising
background image

Publication 1794-UM064B-EN-P - May 2014

36 Communicate With Your Module

1794-IRT8 – Thermocouple/RTD Input Module Image Table Mapping

1146

1794-IRT8 Thermocouple/RTD/mV Input Module Read Words

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

Size

17

16

15

14

13

12

11

10

07

06

05

04

03

02

01

00

Read/Write
Words

Channel 0 Input Data

Read 0

Channel 1 Input Data

Read 1

Channel 2 Input Data

Read 2

Channel 3 Input Data

Read 3

Channel 4 Input Data

Read 4

Channel 5 Input Data

Read 5

Channel 6 Input Data

Read 6

Channel 7 Input Data

Read 7

Overrange Alarm bits (channel 0 = bit 08, and so on)

Underrange Alarm bits (channel 0 = bit 00, and so on)

Read 8

Ch7
Fault

Ch6
Fault

Ch5
Fault

Ch4
Fault

Ch3
Fault

Ch2
Fault

Ch1
Fault

Ch0
Fault

CJC 2
Alarm

CJC 1
Alarm

Diagnostic Status

Read 9

EDT command response

EDT response data

Read 10

Not used

Data Format

Fault
Mode
Ch 0…3

Fault
Mode
Ch 4…7

Reference Jct.

Filter Cutoff

Write 0