Configure the pto channel, I/o assignment, Configure the pto channel on – Rockwell Automation Motion Control PTO Application Building Block User Manual
Page 26

26
Rockwell Automation Publication CC-QS033A-EN-P - February 2014
Chapter 1 Micro800 Controller PTO Axis Setup
Configure the PTO Channel
The starting project from sample code website is configured to work with the Kinetix 3 drive and wiring diagram. The
default configuration includes a PTO axis. You can find out more about the configuration in Micro800 Controller PTO
Axis Setup in
For project that is generated with the CCAT generation function the PTO is not configured. You must configure it
manually by using
as a reference.
I/O Assignment
Each PTO channel has its own fixed and default I/O assignments for its motion functions. For example, PTO channel 0
uses embedded output 0 and 3 for pulse and direction signal and PTO channel 1 uses embedded output 1 and 4. If you
make any changes to the I/O assignment from the original project, also make the changes to corresponding hard-wiring.
The diagram below shows the I/O assignment for a single PTO application, downloaded from sample code website, a more
detail list of I/O assignments for double and triple PTO applications is provided in
Figure 3 - I/O Assignment for a Single PTO Application