Appendix b, Global variables, Appendix – Rockwell Automation Motion Control PTO Application Building Block User Manual

Page 71

Advertising
background image

Rockwell Automation Publication CC-QS033A-EN-P - February 2014

71

Appendix

B

Global Variables

This appendix contains the global variables used for the user program interfacing.

Table 15 - Global Variable

Variable Name

Data Type

Variable Description

(User-defined prefix)_Cfg_MoveMode_Auto

INT

0: Maintenance mode (lets only the axis jog)
1: Velocity Move mode
2: Absolute Move mode
3: Relative Move mode

(User-defined prefix)_Cfg_EnNegative_Auto

BOOL

Enable motion in the negative direction.

(User-defined prefix)_Cfg_EnPositive_Auto

BOOL

Enable motion in the positive direction.

(User-defined prefix)_Cmd_Reset_Auto

BOOL

Execute to clear FB fault.

(User-defined prefix)_Cmd_RsetDrv_Auto

BOOL

Execute to clear servo drive fault.

(User-defined prefix)_Cmd_Home_Auto

BOOL

Execute to home axis.

(User-defined prefix)_Cmd_Move_Auto

BOOL

Execute to move axis according to Move mode, acceleration, deceleration, jerk, position,
direction and velocity value.

(User-defined prefix)_Cmd_Enable_Auto

BOOL

Execute to power on servo drive.

(User-defined prefix)_Cmd_Stop_Auto

BOOL

Execute to stop PTO with reference to emergency stop profile (Setting not available in
faceplate).

(User-defined prefix)_Cmd_Halt_Auto

BOOL

Execute to stop Pulse Train Output (PTO).

(User-defined prefix)_Cfg_HomeMode_Auto

SINT

Selection of homing method.

(User-defined prefix)_Par_AccData_Auto

REAL

Set acceleration value for Move command.

(User-defined prefix)_Par_DecData_Auto

REAL

Set deceleration value for Move and Halt command.

(User-defined prefix)_Par_StopDec_Auto

REAL

Set deceleration value for Stop command. (Setting not available in faceplate)

(User-defined prefix)_Par_DirData_Auto

SINT

Set direction value for Move command.

(User-defined prefix)_Par_JerkData_Auto

REAL

Set jerk value for Move command.

(User-defined prefix)_Par_StopJerk_Auto

REAL

Set jerk value for Stop command. (Setting not available in faceplate)

(User-defined prefix)_Par_PositionData_Auto

REAL

Set Position value Move command.

(User-defined prefix)_Par_HomePosition_Auto

REAL

Set the absolute home position value when axis is homed.

(User-defined prefix)_Par_VelocityData_Auto

REAL

Set velocity value for Move command.

(User-defined prefix)_Cfg_Channel_Auto
Channel number of serial port for communication to drive

UINT

For drive communication.

(User-defined prefix)_Par_Interval_Auto
Set polling interval for drive

UDINT

For drive communication.

(User-defined prefix)_Cfg_NodeAddr_Auto
Set the node address of drive. For communication with controller

USINT

For drive communication.

(User-defined prefix)_Cmd_HscDsEn_Auto
Execute to disable High Speed Counter

BOOL

Applicable only when using an encoder.

(User-defined prefix)_Cmd_HscEn_Auto
Execute to enable High Speed Counter

BOOL

Applicable only when using an encoder.