Chapter 2 System Validation
Configure Your Controller Serial Port
The Micro800 controller communicates with PanelView Component terminal and Kinetix 3 drive through the embedded
serial port and 2080-SERIALISOL plug-in. The embedded serial port is called channel 2 and the first plug-in slot is called
channel 5.
The following settings are used for each port.
Table 3 -
Embedded Serial Port
Table 4 - 2080-SERIALISOL Plug-in Module
Parameter
Setting
Driver
CIP Serial
Baud Rate
38400
Parity
None
Station Address
1
Advanced Settings
Error Detection
CRC
Embedded Responses
After One Received
Duplicate Packet Detection
TRUE
ACK Timeout (x20ms)
50
NAK Retries
3
ENQ Retries
3
Transmit Retries
3
RTS off-Delay
0
RTS Send-Delay
0
Parameter
Setting
Driver
Modbus RTU
Baud Rate
19200
Parity
None
Modbus role
Modbus RTU Master
Advanced Settings
Media
RS485
Data bits
8
Stop bits
1
Response Timer
200
Broadcast Pause
200
Inter-Char Timeout
0
RST Pre-Delay
0
RTS Post-Delay
0