System Validation Chapter 2

3. Type the following for HSC configuration.

4. Press the Enable button.

The HSC status displays the following.

5. Press the X button.

You are returned to Axis Configuration Screen.

6. Press X button again.

7. You are returned to Command & Status Screen.

Explore the Advance Move Screen

The left side shows the servo status indicators describe below.

Attribute

Setting

HSC ID

2

HSC mode

6

Initial Pos

0

Attribute

Setting

HSC Rdy

HSC On

HSC Err

No Fault

HSC Cnt

0 (the value changes as you
rotate your encoder)

Parameter

Description

Range

Move type

This is a multi-selection button. Press this button to switch between Select Move, Velocity, Absolute, and Relative move types.

0… 3

Deceleration

This parameter is the deceleration rate that is used for any move command initiated, in mm/s

2

.

0… 90,000

Acceleration

This parameter is the acceleration rate that is used for any move command initiated, in mm/s

2

.

0… 90,000

Jerk

This parameter is the rate of acceleration or deceleration used for any move command initiated. A 0 value denotes a trapezoidal
motion profile.

0… 90,000

Direction

This parameter controls the direction for velocity move.

1 = Positive direction
-1 = Negative direction
0 = Follow previous direction

Velocity

This parameter is the velocity for any move command initiated, in mm/s.

0… 833

Position

This parameter determines the position value and reference for relative and absolute position control respectively.