Appendix A Kinetix 3 Drive Component-class User-defined Functional Block
Channel
UINT
This is the port or channel on the controller that is connected to the drive. For this UDFB, it is
recommended to use a 2080-SERIALISOL module instead of the embedded serial port.
2, 5, 6, 7, 8, and 9
NodeAddr
USINT
Each drive has a node address that the Modbus Master uses to reference that drive. For each
Modbus network, those addresses must be unique.
1…247
Interval
UDINT
This parameter is used to control how often the UDFB sends Modbus messages to the device.
Zero representing the Continuous Operation mode. In Continuous mode, the drive status updates
as often as possible given the network traffic and buffer.
0…65,536 ms
Table 14 - RA_K3_MBUS_STS_Extended Input
Variable
Type
Description
Range
FBENO
BOOL
This variable reflects the state of the Function Block Enable bit (FBEN).
1, 0
FB_Q
BOOL
This variable shows whether the status message has completed. After the response from the
drive has been received, this bit becomes true. It stays true until another message is sent or until
UDFB sees a rising edge of the enable input.
1, 0
CommLoss
BOOL
This bit signifies a communication timeout between the controller and the drive. This also
triggers FB_Error to be true. This is cleared after a successful completion of a message to the
drive or the UDFB sees a rising edge of the enable input.
1, 0
FB_Error
BOOL
This bit shows that an error occurred within the UDFB. For a more detailed description of the
error code, see FB_ErrCode.
1, 0
FB_ErrCode
UDINT
This variable enumerates the errors that have occurred within the UDFB. This UDFB has the
following error designations:
Bit 0 - Modbus Message Communication Error.
Bit 1 - Invalid Channel.
Bit 2 - Invalid Node Address.
—
VelocityFdbk
INT
This value is the motor feedback velocity in revolutions per minute.
—
VelocityCmd
INT
This value is the motor command velocity in revolutions per minute.
—
VelocityErr
INT
This value is the difference between the motor command and motor feedback velocity, in
revolutions per minute.
—
TorqueCmd
REAL
This value is the commanded current to the motor, in percent of maximum for the drive.
—
PosnFdbk
DINT
This value is the motor feedback position in encoder counts.
—
PosnCmd
DINT
This value is the motor command position in encoder counts.
—
PosnErr
DINT
This value is the difference between the motor command and motor feedback position, in
encoder counts.
—
PlsCmdFreq
REAL
This is the frequency of pulses, in pulses per second, while in Position Follower mode.
—
ElecAngle
REAL
This is the electrical angle of the motor, in degrees.
—
MechAngle
REAL
This is the mechanical angle of the motor, in degrees.
—
ShuntLoad
INT
This is the regenerative loading, in percent of maximum.
—
BusVoltage
INT
This is the bus voltage, in volts.
—
EncTurnCount
INT
This is the absolute encoder turn count. It is active only when the encoder is using absolute
feedback with a battery.
—
AlarmCode
INT
This is the most recent alarm code registered by the drive.
—
AlarmText
STRING
This is the alarm message associated with the most recent alarm code.
—
Table 13 - RA_K3_MBUS_STS_Extended Inputs (continued)
Variable
Type
Description
Range