Chapter 2, System validation, Before you begin – Rockwell Automation Motion Control PTO Application Building Block User Manual

Page 31: What you need, Before you begin what you need, Chapter

Advertising
background image

Rockwell Automation Publication CC-QS033A-EN-P - February 2014

31

Chapter

2

System Validation

In this chapter, you confirm the following:

• Communication between controller and PanelView Component terminal
• Controller generates the appropriate pulse output to control the motor
• Communication between controller and Kinetix 3 servo drive

The operation of the sample code and screens is also explained.

Before You Begin

• Review all steps in

Chapter 1

.

• Verify that all of the devices are connected as shown in the wiring diagram.
• Verify that the Micro800 controller, the Kinetix 3 drive, and the PanelView Component terminal have power

applied to them.

• Review the Getting Started CCAT with System Design Assistant Quick Start, publication

CC-QS035

.

What You Need

• Personal computer with Connected Components Workbench software version 6 or later installed
• 6 in. (or larger) PanelView Component terminal and 1761-CBL-PM02 communication cable
• Kinetix 3 drive and 2080-CCMDSDS-48AA01 communication cable
• Micro830 or Micro850, transistor-type output controller with 2080-SERIALISOL module
• USB printer cable (A to B) for personal computer to Micro800 controller communication

Advertising