Appendix D Configure a Series A Kinetix 3 Drive

8. In the personal computer Communication Setup dialog box, configure the serial port, as follows:

– Serial Port chosen in step

6

– Baud Rate: 57600
– Format: 8 Data Bits, No Parity

9. Click OK.

10. From the Tools menu, choose Rescan.

The drive attaches at Node 1 and appears in the On-Line Drives tree when the scan is complete.

If

Then

Communication was established.

You are prompted to use a wizard to set up the Kinetix 3 drive. You are not required to use it, but it simplifies configuration.

Communication was not established

There is an error in the communication setup, the drivers, or the wiring