Kinetix 3 Drive Component-class User-defined Functional Block Appendix A
RA_K3_MBUS_STS_Extended User-defined Function Block
This UDFB retrieves the extended status information from the drive. The drive supports only two analog
outputs; this lets many more values be updated. The output values are updated at the interval specified by the
input interval.
Table 13 - RA_K3_MBUS_STS_Extended Inputs
Variable
Type
Description
Range
FBEN
BOOL
The Function Block Enable bit (FBEN) controls the operation of the function. On the rising edge of
this bit, the function block initialization takes place. While this bit is held high, the function
block continues to execute.
1, 0