Y s i – YSI ADV6600 User Manual

Page 4

Advertising
background image

Table of Contents

ADV6600

Y S I

Environmental

Page iv

3-4. Connecting to the System............................................................................16

Settings...................................................................................................................................... 16

Baud Rate .................................................................................................................................. 17

3-5. Understanding the Firmware of the ADV6600.........................................18
3-6. Setting up the Water Quality Sensor Firmware.......................................18

3-6.1. Setting Up the Water Quality Sensors ............................................................................ 18

3-6.2. Water Quality Menu Flowchart ...................................................................................... 20

3-6.3. Setting Up Installed Sensors ........................................................................................... 21

3-6.4. Setting Up Reports .......................................................................................................... 21

3-6.5. Advanced Menu Features................................................................................................ 24

3-7. Setting up the ADV Sensor Firmware .......................................................28

3-7.1. Setting the System Time ................................................................................................. 28

3-7.2. Setting Up the ADV Parameter Output........................................................................... 28

3-8. Exiting the ADV6600 Firmware ................................................................30
3-9. ADV6600 Firmware Upgrades ...................................................................30

Section 4.

Calibration and Diagnostics ..........................................................35

4-1. Beam Check Basics......................................................................................35
4-2. Running the ADV Beam Check .................................................................35

4-2.1. Laboratory Beam Check Procedure ................................................................................ 36

4-2.2. Creating a Beam Check File ........................................................................................... 38

4-2.3. Opening a Recorded Beam Check File ........................................................................... 38

4-2.4. Viewing a Recorded Beam Check File ........................................................................... 40

4-2.5. Interpreting Your Laboratory Beam Check Data ............................................................ 40

4-2.6. Beam Check Feature Summary....................................................................................... 42

4-3. Calibrating the Compass ............................................................................43

Compass Calibration Procedure ................................................................................................ 44

4-4. Changing the Pressure Sensor Offset ........................................................45
4-5. Water Quality Sensors – Preparing for Calibration ................................46

4-5.1. Health and Safety............................................................................................................ 47

4-5.2. Materials Required.......................................................................................................... 47

4-5.3. Calibration Tips .............................................................................................................. 47

4-5.4. Use of the Calibration Cup.............................................................................................. 48

4-5.5. Recommended Volumes of Calibration Reagents........................................................... 49

4-6. Water Quality Sensors - Calibration Procedures.....................................49

4-6.1. Temperature .................................................................................................................... 50

4-6.2. Conductivity.................................................................................................................... 50

4-6.3. Dissolved Oxygen for Unattended Monitoring Studies .................................................. 51

4-6.4. Dissolved Oxygen for Spot Sampling Studies ................................................................ 52

4-6.5. pH ................................................................................................................................... 52

4-6.6. ORP................................................................................................................................. 53

Advertising