In MegaRAC GUI, the PEF Management is used to configure the following

• Event

Filter

• Alert

Policy

• LAN

Destination

To open PEF Management Settings page, click Configurations > PEF from the menu bar.
Each tab is explained below.

3.7.14.1

Event Filter Tab

A PEF implementation is recommended to provide at least 16 entries in the event filter
table. A subset of these entries should be pre-configured for common system failure
events, such as over-temperature, power system failure, fan failure events, etc. Remaining
entries can be made available for ‘OEM’ or System Management Software configured
events. Note that individual entries can be tagged as being reserved for system use - so
this ratio of pre-configured entries to run-time configurable entries can be reallocated if
necessary.

PEF Management – Event Filter

The fields of PEF Management – Event Filter Tab are explained below.

This page contains the list of configured PEF’s.

PEF ID: This field displays the ID for the newly configured PEF entry (read-only).

Filter configuration:

Check box to enable the PEF settings.

Event Filter Action: Check box to enable PEF Alert action. This is a mandatory field.

Event Severity:

To choose any one of the Event severity from the list.