B. Criteria

Task

Description

PoE-Connect

I Class: Configure minimum and maximum mA
current of the configured class that is described at
previous tab

Tpdc: Configure the minimum and maximum
values in milliseconds to classify the PD (Powered
Device)

Power meter Setting: this function is available only when XM-2WL1 modules are installed. The

function is to test the electric parameters of DUT. Please select the XM-2WL1 module from the

scroll-down menu.

Pow

er Setting: This function allows you to check DUT‟s power status during the test. Please note

that if there is no power testing module card installed on the chassis, the Power Setting section will

be gray and thus unable to access.

Enable Power Monitor & Check: Click this check-box to enable Power Setting function. You

can set which port on the power testing module card to use by clicking the scroll-down menu.

RMS Voltage/Current, Peak Voltage/Current, and Active Power: You can set the criteria for

power testing in these fields.

C. Help

You can see the system status of your

task on this field.