Alter. : A network cable contains 4 twisted pair (8 totally) copper wire. The Alternative function can

lead input power from DUT to different pairs for the requirement of test allows you to choose which

pins provide the power. You can choose Mode A (Powered via Pin 1, 2, 3, and 6), or Mode B

(Powered via Pin 4, 5, 7, and 8). For more information regarding to network cable lines and how

they are related to RJ-45 jack, please refer to the Alternative explanation in 5.4.1 POE Connect.

Load (Watt):set the power(watt) that will be loaded.

Prepare Load (Watt): Set the power for starting a test.

Prepare Load Time (ms): Set the time for starting a test.

Line Emulation(M): You can simulate the result of a test based on the length of a connection

cable.

Cable Select(ohm/m): Select the type of cable.

Other options on this Setup tab menu include:

Cable Select(ohm/m): Select the type of cable.

Operating Mode: You can scroll down this field to choose the Synchronous and Time-Delay mode

for this testing task. Sequence Delay Time: This option will be only available when you select the

Time Delay mode from the Operating Mode field.

Wait for Check Result: System will wait for the set amount of time before checking the test result.

Test Period: You can set the amount of time for testing here.

Halt on if Fail: The test will halt if the test fails.

Delay counter Report: delay the data report of the counters.

Port Select: By clicking this button, a Select Ports for Testing window will pop up, allowing you to

select the module cards and the ports you would like to use for the task.

Quick Setup: Selecting this option will pop up a window in which is contains the simplified version of

this Setup functions.