Chapter 3: System Cable Installation

Specifications for AC Power

Table 3-5. Specifications for 200/240 VAC User-Supplied Power Supply

Auto-Ranging

Nominal

Voltage

Ranges

Minimum

Operating

Voltage

1

Maximum
Operating

Voltage

Frequency/

Phasing

Recommended

External Circuit

Breaker, User-

Supplied

200 V to 240 V

180 V

264 V

50/60 Hz, 1-phase

10 Amps

1

Specifications are established at nominal line voltage. Low line voltage can affect robot

performance.

NOTE: The Adept robot system is intended to be installed as a piece of equipment
in a permanently-installed system.

DANGER: AC power installation must be performed by
a skilled and instructed person—see the

Adept Robot

Safety Guide

. During installation, unauthorized third

parties must be prevented from turning on power
through the use of fail-safe lockout measures.

Facility Overvoltage Protection

The user must protect the robot from excessive overvoltages and voltage spikes. If the country
of installation requires a CE-certified installation, or compliance with IEC 1131-2, the following
information may be helpful: IEC 1131-2 requires that the installation must ensure that
Category II overvoltages (i.e., line spikes not directly due to lightning strikes) are not exceeded.
Transient overvoltages at the point of connection to the power source shall be controlled not to
exceed overvoltage Category II, i.e., not higher than the impulse voltage corresponding to the
rated voltage for the basic insulation. The user-supplied equipment or transient suppressor
shall be capable of absorbing the energy in the transient.

In the industrial environment, nonperiodic over-voltage peaks may appear on mains power
supply lines as a result of power interruptions to high-energy equipment (such as a blown fuse
on one branch in a 3-phase system). This will cause high-current pulses at relatively low
voltage levels. The user shall take the necessary steps to prevent damage to the robot system
(such as by interposing a transformer). See IEC 1131-4 for additional information.