Chapter 7: Maintenance

2. Switch off the SmartController.

3. Switch off the 24 VDC input supply to the MB-40R/eMB-40R.

4. Switch off the 200/240 VAC input supply to the MB-40R/eMB-40R.

5. Disconnect the 24 VDC supply cable from the MB-40R/eMB-40R +24 VDC input

connector. See Figure 4-2 for locations of connectors.

6. Disconnect the 200/240 VAC supply cable from the MB-40R/eMB-40R AC input

connector.

Lock out and tag out power.

7. Remove the battery cover from the robot, by removing 4 hex socket-head bolts (M3 x 8),

as shown in the following figure.

NOTE: On the cleanroom robot, the cover has a packing for sealing. Take care not
to lose or pinch it.

Battery
Cover

Figure 7-3. Removing Battery Cover

8. Attach the two new backup batteries to unused connectors on the battery board. See the

following figure for details.

NOTE: Always leave at least two batteries connected at all times. Failure to do so
may lose the encoder positional data, requiring factory recalibration.

Adept Cobra s350 User's Guide, Rev. D

Page 70 of 94