7.1 Periodic Maintenance Schedule

The following table gives a summary of the preventive maintenance procedures and
guidelines on frequency.

Table 7-1. Inspection and Maintenance

Item

Period

Reference

Check E-Stop, enable and key switches, and barrier
interlocks

3 months

Section 7.2

Check robot mounting bolts

3 months

Section 7.3

Lubricate Joint 3 (Z-axis) ball screw

6 months

Section 7.4

Replace Encoder battery

2 - 4 years

Section 7.5

Inspect timing belts on 3rd and 4th axes

12 months

Section 7.6

WARNING: The procedures and replacement of parts
mentioned in this section should be performed only by
skilled or instructed persons, as defined in the Adept
Robot Safety Guide. The access covers on the robot are
not interlocked – turn off and lock out/tag out power if
covers have to be removed.

7.2 Checking of Safety Systems

These tests should be done every six months.

1. Test operation of:

l

E-Stop button on Front Panel

l

E-Stop button on pendant

l

Enabling switch on pendant

l

Auto/Manual switch on Front Panel

NOTE: Operating any of the above switches should disable High Power.

2. Test operation of any external (user supplied) E-Stop buttons.

3. Test operation of barrier interlocks, etc.