2 connections, 3 requirements – Adept s350 Cobra User Manual

Page 86

Advertising
background image

Chapter 9: Cleanroom Robots

9.2 Connections

Figure 9-2. Cleanroom Connections

9.3 Requirements

Table 9-2. Cleanroom Robot Requirements

Vacuum source

0.10 m

3

/min (3 ft

3

/min) minimum volumetric flow

rate

350 mm of water (13.5 inches of water) differential
pressure measured between the robot and the
vacuum source

15 mm OD tube fitting at the back of the robot

Quill inside diameter

The inside diameter of the quill must be plugged
by the user’s end-effector in order to maintain
cleanliness at the tool flange.

Adept Cobra s350 User's Guide, Rev. D

Page 86 of 94