Chapter 4: MotionBlox-40R

Table 4-1. Connectors on the MB-40R/eMB-40R Interface Panels

24 VDC

For connecting user-supplied 24 VDC power. The mating connector is
provided.

Ground
Point

For connecting cable shield from user-supplied 24 VDC cable.

200/240
VAC

For connecting 200-240 VAC, single-phase, input power. The mating
connector is provided.

SmartServo

For connecting the IEEE 1394 cable from the controller.
(SmartServo 1.1) to a SmartServo/Servo on the MB-40R/eMB-40R.

XIO

For user I/O signals for peripheral devices. This connector provides 8 outputs
and 12 inputs. See Connecting Digital I/O to the System on page 40 for
connector pin allocations for inputs and outputs. That section also contains
details on how to access these I/O signals. (DB-26, high density, female)

XSYSTEM

eMB-40R only, includes the functions of the XPANEL and XSLV on the MB-
60R. Connects to the controller XSYS connector.
This requires either an eAIB XSLV Adapter cable to connect to the XSYS cable,
or an eAIB XSYS cable (HDB44-to-DB9, male), which replaces the XSYS cable.

ENET

eMB-40R only. Reserved for future use.

XBELTIO

eMB-40R only. Adds two belt encoders, EXPIO at the back of the robot (not
available on an MB-40R), and an RS-232 interface, which is reserved for
future use.

XSLV

MB-40R only, for connecting the supplied XSYS cable from the controller
XSYS connector. (DB-9, female).

XPANEL

MB-40R only. Not used (DB-26, high density, male).

RS-232

MB-40R only. Reserved for future use (DB-9, male).

4.3 MB-40R/eMB-40R Operation

Status LED on MB-40R/eMB-40R

The Status LED indicator is located on the top of the MB-40R/eMB-40R. See the following
figure. This is a bi-color, red and green LED. The color and blinking pattern indicates the
status of the robot. See the following table.

Adept Cobra s350 User's Guide, Rev. D