New backup
batteries

Old backup
batteries

Figure 7-4. Attaching New Batteries

9. Disconnect the two old batteries from the battery board and then remove them from the

holders.

10. Put the new batteries into the battery holders, as shown in the following figure.

New connectors

Figure 7-5. New Batteries in Holders

11. Reinstall the battery cover on the robot.

Tightening toque: Hex socket-head bolt (M3 x 8): 1.6 ± 0.3 N·m (1.2 ± 0.2 ft-lbf)

NOTE: On the cleanroom robot, reinstall the packing under the cover. Take care not
to pinch it.