Optional i/o products, Xio input signals – Adept s350 Cobra User Manual

Page 44

Advertising
background image

Chapter 4: MotionBlox-40R

Optional I/O Products

These optional products are also available for use with digital I/O:

l

XIO Breakout Cable, 5 meters long, with flying leads on user’s end (see XIO Breakout
Cable on page 47). It is not compatible with the XIO Termination Block mentioned
below.

l

XIO Termination Block, with terminals for user wiring, plus input and output status
LEDs. Connects to the XIO connector with 6-foot cable. See the

Adept XIO Termination

Block Installation Guide

for details.

XIO Input Signals

The 12 input channels are arranged in two banks of six. Each bank is electrically isolated from
the other bank and is optically isolated from the MB-40R/eMB-40R ground. The six inputs
within each bank share a common source/sink line.

The inputs are accessed through direct connection to the XIO connector (see the following
table), or through the optional XIO Termination Block. See the documentation supplied with
the Termination Block for details.

The XIO inputs cannot be used for REACTI programming, high-speed interrupts, or vision
triggers. Refer to the V+/eV+ user guides in the Adept Document Library (ADL) on the Adept
website. For more details on the ADL, see Adept Document Library on page 16.

XIO Input Specifications

Table 4-8. XIO Input Specifications

Parameter

Value

Operational voltage range

0 to 30 VDC

OFF state voltage range

0 to 3 VDC

ON state voltage range

10 to 30 VDC

Typical threshold voltage

V

in

= 8 VDC

Operational current range

0 to 7.5 mA

OFF state current range

0 to 0.5 mA

ON state current range

2.5 to 6 mA

Typical threshold current

2.0 mA

Impedance (V

in

/I

in

)

3.9 K

minimum

Current at V

in

= +24 VDC

I

in

6 mA

Turn on response time (hardware)
Software scan rate/response time

5 µsec maximum
16 ms scan cycle/
32 ms max response time

Turn off response time (hardware)
Software scan rate/response time

5 µsec maximum
16 ms scan cycle/
32 ms max response time

Adept Cobra s350 User's Guide, Rev. D

Page 44 of 94